WEG WPS Power Supplies

Compact and high-power DIN-rail supplies engineered for resilient 24 VDC control power.

WEG WPS switch-mode power supplies combine wide input ranges, high efficiency, and diagnostic feedback to keep automation cabinets running. From slim 24 VDC supplies for PLC racks to three-phase units capable of redundant operation, WPS hardware forms the backbone of reliable machine control, motion, and safety systems.

Illustration of WEG WPS power supply

Output Platforms

WPS Compact
Slim 15–240 W supplies with 24 VDC outputs up to 10 A supporting PLC, I/O, and instrumentation loads.
WPS Pro
480 W and 960 W models delivering 20–40 A with integrated current sharing for redundant control power buses.
Supplementary Modules
Buffer packs, DC UPS modules, and ORing devices that extend ride-through and isolate faults between supplies.

Input & Efficiency

Wide Input Range:
85–264 VAC or 90–375 VDC single-phase; 320–575 VAC three-phase for high-power models.
Efficiency:
Up to 94% typical with power factor correction on select units.
Temperature:
-25 °C to +70 °C operation with derating curves and conformal coating options.

Protection & Monitoring

Protection:
Short-circuit, overload, and overvoltage protection with hiccup or constant current limiting.
Diagnostics:
Front-panel LEDs, DC OK relay contacts, and remote monitoring terminals for PLC integration.
Standards:
UL 508, UL 60950, CSA C22.2, CE, and RoHS compliance for global deployments.

Panel Integration

  • DIN-rail mounting clips and pluggable terminals accelerate assembly.
  • Adjustable output trim facilitates voltage drop compensation across long runs.
  • Parallel-ready models include load-sharing terminals for redundant operation.
  • Compatible with WEG redundancy, buffer, and UPS accessories.

Engineering Advantages

Global Flexibility

Universal input ranges and certifications streamline export machine builds and multi-plant deployments.

Resilient Control Power

High MTBF ratings, conformal coating, and buffering options keep PLCs and safety systems online.

Diagnostics & Visibility

Integrate DC OK contacts and alarms with PLC500 diagnostics, HMIs, and SCADA dashboards.

Service-Friendly Design

Front-access terminals and tool-free mounting simplify replacements during maintenance windows.

WPS Model Comparison

Model Output Input Key Features Typical Loads
WPS024-060C 24 VDC, 2.5 A (60 W) 85–264 VAC, 90–375 VDC Slim 45 mm width, DC OK relay, adjustable 24–28 VDC PLC500 CPU, remote I/O nodes, HMI power supplies
WPS024-120C 24 VDC, 5 A (120 W) 85–132 / 176–264 VAC auto-range Power factor correction, pluggable terminals, 94% efficiency Servo controller I/O, relay banks, gateway devices
WPS024-480P 24 VDC, 20 A (480 W) 320–575 VAC three-phase Current sharing terminals, remote on/off, conformal coating Redundant safety PLC racks, motion cabinets, MCC control sections
WPS-Buffer 20S 24 VDC ride-through up to 20 s 24 VDC bus Maintenance-free capacitors, alarm contact, plug-and-play wiring Critical HMI stations, network switches, safety controllers

Integration Guidance

  • Segment critical and non-critical loads with dedicated circuit protection and redundancy modules.
  • Leverage buffer packs to ride through transfer switches and voltage sags on utility feeds.
  • Map DC OK contacts and alarm relays to PLC500 diagnostics for proactive maintenance.
  • Coordinate WPS supplies with MPW motor protection and CW contactor coils for safe shutdown.
Review Control Power Specs

Deliverables from Gross Automation

  • Load calculation spreadsheets with diversity factors and redundancy recommendations.
  • Single-line diagrams highlighting control power distribution and isolation.
  • Panel layouts showing DIN-rail spacing, ventilation, and wiring separation.
  • Commissioning checklists covering voltage verification, alarm testing, and battery maintenance.

Featured Resources

WPS Selection Guide

Choose the right WPS supply with current, efficiency, and accessory references.

Request Guide

Redundancy Worksheet

Document load priorities, ride-through expectations, and alarm settings for dual supplies.

Download Worksheet

Buffer Module Application Note

Learn how to integrate capacitor-based ride-through modules with PLC diagnostics.

View Application Note

Stabilize Your 24 VDC Infrastructure

Send us your load list or panel drawings. Our sales engineers will size WPS supplies, redundancy modules, and transformers for reliable operation.

Engage Our Team