SIL/PL Certified
SRW safety relays achieve SIL3 / PL e with redundant contact architecture and monitoring diagnostics.
SRW safety relays, emergency-stop devices, and LED signaling solutions designed for machine safeguarding.
WEG safety components help machine builders and end users meet EN ISO 13849 and IEC 62061 requirements. Combine SRW safety controllers, emergency stops, guard switches, and signaling towers with detailed documentation and validation support from Gross Automation.
SRW safety relays achieve SIL3 / PL e with redundant contact architecture and monitoring diagnostics.
Pre-packaged emergency-stop stations and modular signaling towers reduce build time and wiring effort.
Safety relay status LEDs and optional communication provide clear feedback for troubleshooting.
Guard locking actuators, enabling switches, and stack light modules cover complete safety zones.
Modular SRW relays with configurable logic for emergency stops, guard doors, and light curtains.
Twist- and key-release E-stop operators packaged with contact blocks, guards, and enclosures.
LED stack lights, beacons, and sounders that communicate machine state in high-noise areas.
| Component | Safety Ratings | Inputs / Outputs | Highlights |
|---|---|---|---|
| SRW01 Safety Relay | SIL3, PL e, Category 4 | 4 dual-channel inputs, 3 N.O. safety outputs, 1 aux | Configurable via front DIP switches with LED diagnostics |
| SRW02 Configurable Controller | SIL3, PL e | Up to 32 safety inputs with expansion, 6 dual safety outputs | Software configuration with application libraries and password protection |
| Emergency Stop Operators | SIL3 capable when wired dual-channel | 1 or 2 N.C. positive-opening contacts plus optional N.O. | 40/60 mm mushroom heads, twist/key reset, IP66/IP69K |
| LED Stack Lights | UL Type 4/4X, IP65/IP66 | Up to 5 LED modules plus 90 dB sounder | 24/120/240 VAC/DC modules with quick-change LED cartridges |
Integrate interlocks, light curtains, and SRW logic to monitor guarding devices and shut down hazards quickly.
Deploy emergency-stop circuits and signaling towers in chemical, food, and packaging environments with washdown requirements.
Use wireless signaling and rugged emergency stops on cranes, AGVs, and maintenance vehicles.
Upgrade legacy machinery to modern safety standards with documented validation and risk assessments.
We facilitate on-site or virtual assessments to prioritize safeguards and document hazards.
Receive SISTEMA calculations, wiring verification, and proof testing records for audits.
Our team designs, installs, and commissions WEG safety upgrades with training for operators.
The SRW safety page captures controller comparisons, certification levels, and turnkey service deliverables that help you close out risk assessments with confidence.
Gross Automation provides risk assessments, SISTEMA documentation, and onsite validation to ensure your machines meet regulatory requirements.
Schedule AssessmentShare your risk assessment or retrofit goals and we will design a compliant WEG safety solution.
Talk with an Engineer